Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Orbit ; : 1-4, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37262366

RESUMO

Intraorbital lymphatic-venous malformations are rare lesions that represent a therapeutic challenge given their location and high rate of recurrence, with only a few cases in adult patients having been published in the literature. We present the case of a 30-year-old male with a right intraorbital lymphatic-venous malformation treated with sirolimus at a dose of 4 mg/day with complete clinical and radiologic remission. Mild cold-like symptoms ensued during the first week of treatment and elevation of liver function enzymes and D-dimer occurred in the context of acute SARS-CoV-2 pneumonia. No major adverse effects were documented. After 18 months of treatment, the patient remains asymptomatic and ophthalmologic examinations including optical coherence tomography and visual field test are within normal values.

2.
Can J Ophthalmol ; 57(3): 201-206, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33865759

RESUMO

OBJECTIVE: This study was designed to evaluate potential differences in circumpapillary retinal nerve fibre layer (cpRNFL) thickness and segmented macular retinal layers between dominant and nondominant eyes on spectral-domain optical coherence tomography in a pediatric population. DESIGN: Cross-sectional study. PARTICIPANTS: 89 healthy children attending a general pediatric clinic. METHODS: Participants underwent sighting dominant testing and macular and cpRNFL spectral-domain optical coherence tomography. Segmented macular layer thicknesses and cpRNFL thickness were compared for individual patients based on their ocular dominance. RESULTS: Ocular dominance occurred particularly in the right eye (64.7%). Dominant and nondominant eyes did not differ significantly in axial length or spherical equivalent refraction; axial length: 22.99 ± 1.17 mm versus 22.98 ± 1.19 mm; p = 0.51 and spherical equivalent refraction: -0.09 ± 2.68 D versus 0.32 ± 2.93 D; p = 0.41. In the comparison of the macular ganglion layer the average thickness in the 1 mm central Early Treatment Diabetic Retinopathy Study area was significantly different between the dominant and nondominant eye (16.56 ± 6.02 µm vs 17.58 ± 8.32 µm; p = 0.02). However, when compensating with Bonferroni, this difference was no longer statistically significant. There were no differences in the analyses of average global and sectorial cpRNFL thickness in dominant and nondominant eyes. CONCLUSION: Dominant eyes demonstrated no significantly thicker average macular retinal nerve fiber layer (mRNFL), Ganglion cell layer (GCL) thickness or cpRNFL thickness. No ocular characteristic was found to be associated with the relative dominance of an eye in eyes with low anisometropia.


Assuntos
Fibras Nervosas , Células Ganglionares da Retina , Criança , Estudos Transversais , Dominância Ocular , Humanos , Retina , Tomografia de Coerência Óptica/métodos
3.
PLoS One ; 13(4): e0196112, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29672563

RESUMO

OBJECTIVE: To analyse the morphological features and diagnostic ability of eight macular retinal layers using a new segmentation software Heidelberg's Spectralis Optical Coherence Tomography (SD-OCT) in healthy, ocular hypertensive and primary open angle glaucoma patients. METHODS: Single-center, cross-sectional, non-interventional study. 193 eyes from 193 consecutive patients (56 controls, 63 ocular hypertensives, 32 early primary open glaucoma patients and 42 moderate-advanced primary open glaucoma patients). Those patients presenting any retinal disease were excluded. Macular segmentation of the retinal layers was automatically performed using the new segmentation Heidelberg's Spectralis OCT software providing measurements for eight retinal layers. The software provides thickness maps divided into nine subfields. RESULTS: Statistically significant differences in inner layers' thickness was found between all 4 four groups. Superior and inferior sectors of macular retinal nerve fiber layer; nasal, temporal, superior and inferior sectors of ganglion cell layer and inner plexiform layer were significantly different when comparing ocular hypertensive patients and early glaucoma patients. Areas under the ROC curves for early glaucoma diagnosis were 0.781±0.052 for macular retinal nerve fiber layer outer inferior sector, 0.760±0.050 for ganglion cell layer outer temporal sector, 0.767±0.049 for the inner plexiform layer outer temporal sector and 0.807±0.048 for the combination of all three. No differences were found between groups when considering outer retinal layers. CONCLUSIONS: The automated segmentation software from Heidelberg's Spectralis OCT provides a new diagnostic tool for the diagnosis of ocular hypertensive and glaucoma patients.


Assuntos
Glaucoma/diagnóstico , Processamento de Imagem Assistida por Computador , Hipertensão Ocular/diagnóstico , Retina/diagnóstico por imagem , Retina/patologia , Software , Tomografia de Coerência Óptica , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Tomografia de Coerência Óptica/métodos
4.
Eur J Ophthalmol ; 28(1): 42-46, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28862734

RESUMO

PURPOSE: To evaluate whether the new rim analysis software with spectral-domain optical coherence tomography (SD-OCT) shows advantages over the retinal nerve fiber layer (RNFL) thickness in patients with moderate myopia. METHODS: In this prospective cross-sectional study, we studied 65 healthy subjects, 37 with spherical refractive errors in the range of -3 to -6 D (moderate, G1) and 28 with less than -3 D (low/non-myopic, G0). All patients were examined with Heidelberg Spectralis SD-OCT, including Glaucoma Premium Module Edition (GPME) software. With GPME, we analyzed the neuroretinal rim (Bruch membrane opening-minimum rim width [BMO-MRW]) and RNFL. RESULTS: The average age of subjects was 30.2 ± 9.3 years for G0 and 29.9 ± 7.1 years for G1 (p = 0.903). Mean sphere was -0.5 ± 0.3 D (-1.25 to 0 D) G0 and -3.9 ± 0.3 D (-6.00 to -3 D) G1 (p<0.001). The RNFL thickness comparison between G0 and G1 showed a significantly lower thickness in G1 (p = 0.018). The BMO-MRW measurements were similar in both groups (p = 0.331). With the BMO-MRW examination, the number of sectors classified as pathologic per subject in G1 were significantly lower compared to RNFL analysis (p = 0.023). CONCLUSIONS: Ring analysis based on BMO-MRW measurements shows a lower rate of false-positives compared to RNFL thickness when studying healthy moderate myopic eyes and it would be advisable to take this into consideration when analyzing these patients.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Miopia/patologia , Fibras Nervosas/patologia , Disco Óptico/patologia , Células Ganglionares da Retina/patologia , Software , Tomografia de Coerência Óptica/métodos , Adolescente , Adulto , Lâmina Basilar da Corioide , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
5.
Diabetes Ther ; 8(5): 1087-1096, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28918546

RESUMO

INTRODUCTION: The objective of this study is to evaluate the influence of repeated intraocular dexamethasone implant (Ozurdex) injections on metabolic control in type 2 diabetic patients. METHODS: Retrospective study of 165 type 2 diabetic patients starting Ozurdex treatment who received no less than three consecutive injections. Glycated hemoglobin (HbA1c), serum creatinine, total cholesterol, high-density lipoprotein (HDL) cholesterol, low-density lipoprotein (LDL) cholesterol, and triglycerides (TGs) were evaluated during 15 months of follow-up after Ozurdex treatment onset. RESULTS: Fifty-seven patients met inclusion criteria. Mean baseline values for HbA1c, creatinine, total cholesterol, HDL cholesterol, and TGs before treatment (7.1%, 1.3, 176.7, 51.1, and 125.6 mg/dl, respectively) were similar to mean values after Ozurdex onset (Wilcoxon test p values were 0.68, 0.41, 0.06, 0.87, and 0.33, respectively) and remained stable during the follow-up period. Mean LDL cholesterol levels increased slightly after Ozurdex treatment onset (90.1 vs 88.2 mg/dl, p = 0.04) but after 15 months of follow-up they had returned to baseline values. Transient increase in LDL cholesterol was remarkable in the group of 24 bilaterally treated patients (96.8 vs 88.4 mg/dl, p = 0.03). A third of these patients increased their baseline LDL values by more than 20%. Even with continuous injections of Ozurdex, LDL cholesterol levels also declined back to baseline by month 15. CONCLUSION: Ozurdex injections had no influence on HbA1c or renal function. Lipid profile changes were mild and transient. However, a significant temporary increase has been found in LDL cholesterol levels in patients receiving simultaneous bilateral injections. Lipid levels should be monitored in patients starting with bilateral Ozurdex injections especially in those with recent history of acute myocardial infarction.

6.
PLoS One ; 12(7): e0180450, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28678834

RESUMO

PURPOSE: Develop the first normative database of the thickness of every inner retinal layer in the macular area in a healthy, Caucasian population between 18 to 87 years old, using Spectralis Optical Coherence Tomography (OCT). METHODS: On this transversal, observational study, 300 patients between 18 to 87 years old and without an ophthalmological condition were recruited. Macular OCT scans were performed on all patients (Spectralis OCT, Heidelberg Engineering). An axial length measurement, and keratometry were performed using an optical biometer. The volume and thickness of the different macular sectors of the inner retinal layers (retinal nerve fiber layer (RNFL), ganglion cells layer (CGL) and inner plexiform layer (IPL)) were analyzed with the Spectralis OCT segmentation software. An eye was randomly selected for each patient. RESULTS: 297 patients (179 females and 118 males) were included in the study. The mean age was 56.07 years (range: 40.50-72). The multivariate analysis showed a positive correlation between the RNFL thickness and the axial length (p < 0.001). The mean central retinal thickness was 278.2 µm (range: 266-291), the mean central RNFL thickness was 12.61 µm (range: 11-14), the mean central CGL thickness was 17.63 µm (range: 14-21) and the mean central IPL thickness was 22.02 µm (range: 20-25). The multivariate analysis showed a negative correlation between age and CGL thickness and inner IPL thickness (p< 0.001). CONCLUSION: This study provides a normative database of the volume of each of the inner retinal layers on a Caucasian population.


Assuntos
Bases de Dados Factuais , Retina/anatomia & histologia , Tomografia de Coerência Óptica/métodos , População Branca , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
12.
Invest Ophthalmol Vis Sci ; 55(12): 8343-8, 2014 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-25425301

RESUMO

PURPOSE: To assess the capacity of internal retinal layer thickness measurements made at the macula using new spectral-domain optical coherence tomography (OCT) software to distinguish between healthy subjects and those with suspected glaucoma. The diagnostic performance of such measurements also was compared with that of conventional peripapillary retinal nerve fiber layer (RNFL) thickness measurements. METHODS: The study included 38 subjects with suspected glaucoma and 38 age-matched healthy subjects. In one randomly selected eye of each participant, thickness measurements at the level of the macula were made of the nerve fiber layer (mRNFL), the ganglion cell layer (GCL), and the ganglion cell complex (GCC; GCL + internal plexiform layer) through automated OCT segmentation. Peripapillary RNFL thickness (pRNFL) also was determined using the conventional scan. RESULTS: As the only variable showing intergroup variation, mRNFL in the glaucoma suspects was significantly thinner in the quadrants inner inferior (P = 0.003), inner temporal (P = 0.010), and outer inferior (P = 0.017). The variable best able to discriminate between the two groups was inner inferior mRNFL thickness, as indicated by an area below the receiver operating characteristic (ROC) curve of 0.742. CONCLUSIONS: Macular RNFL thickness measurements showed an improved diagnostic capacity over the other variables examined to distinguish between healthy subjects and glaucoma suspects.


Assuntos
Diagnóstico por Computador/métodos , Fibras Nervosas/patologia , Hipertensão Ocular/diagnóstico , Células Ganglionares da Retina/patologia , Software , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/fisiopatologia , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...